Sign In | Join Free | My burrillandco.com
Home > Thermistor Temperature Sensors >

42002-0024S 8K Thermistor Temperature Sensors Mastertemp Stack Flue Sensor 300C

Dongguan Ampfort Electronics Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 42002-0024S 8K Thermistor Temperature Sensors Mastertemp Stack Flue Sensor 300C from wholesalers
     
    Buy cheap 42002-0024S 8K Thermistor Temperature Sensors Mastertemp Stack Flue Sensor 300C from wholesalers
    • Buy cheap 42002-0024S 8K Thermistor Temperature Sensors Mastertemp Stack Flue Sensor 300C from wholesalers
    • Buy cheap 42002-0024S 8K Thermistor Temperature Sensors Mastertemp Stack Flue Sensor 300C from wholesalers
    • Buy cheap 42002-0024S 8K Thermistor Temperature Sensors Mastertemp Stack Flue Sensor 300C from wholesalers
    • Buy cheap 42002-0024S 8K Thermistor Temperature Sensors Mastertemp Stack Flue Sensor 300C from wholesalers

    42002-0024S 8K Thermistor Temperature Sensors Mastertemp Stack Flue Sensor 300C

    Ask Lasest Price
    Brand Name : AMPFORT
    Model Number : CWFB1802JD8-650T2I
    Certification : RoHS
    Price : Negotiable
    Payment Terms : T/T, MoneyGram, Western Union
    Supply Ability : 400,000 Pieces Per Month
    Delivery Time : Stocks
    • Product Details
    • Company Profile

    42002-0024S 8K Thermistor Temperature Sensors Mastertemp Stack Flue Sensor 300C


    42002-0024S Cross Stack Flue Thermistor Temperature Sensors 8K For Pool Spa Heater


    Description Of The 42002-0024S Cross Stack Flue Thermistor Temperature Sensors


    Location : The Indoor Stack Flue Switch (ES2) / Stack Flue Sensor (SFS) is located on the exhaust Elbow.

    Function : The Stack Flue Sensor prevents the flue gas output from exceeding 500 degrees F +/-18 degrees F.

    Replaces Pentair/Sta-Rite part number :42002-0024S Stack flue sensor replacement.
    Fits Pentair MasterTemp pool and spa heater electrical systems
    Also fits Pentair Sta-Rite Max-E-Therm pool and spa heater electrical systems model SR200, SR333, SR400
    Please note : This is a high-quality replacement ,NOT an Original product. All mentions of brand names or model descriptions are made strictly to illustrate compatibility.

    THIS ITEM IS A PART FOR THE FOLLOWING PRODUCTS


    SIZE Of The 42002-0024S Cross Stack Flue Thermistor Temperature Sensors


    NOCOMPONENTMATERIAL AND SPECIFICATIONSQ'TYREMARK
    2-1ELEMENTR:8KΩ R:5300K DDR1 PCS 
    2-2LEAD WIRETPEF AWG22*1C 320℃65mm(White )
    2-3COATINGEpoxy resin(Black)
    2-4HOUSINGJM19105 Φ6.35*54.6+S13+24UNF SUS3041 PCS
    2-5TERMINOLAMP 250 #22-#182 PCS(Red)

    Check it before purchasing
    * Length of the Stainless Steel body: 2.2in
    * Carefully measure your old stack flue sensor and compared it to the photograph and description
    * Make sure the power is shut off before replacement.
    * Wear work gloves to protect your hands.
    * The part is compatible spare part (not original), the brand names mentioned and any related models designation above are only for purposes of demonstrating compatibility.


    Features Of The 42002-0024S Cross Stack Flue Thermistor Temperature Sensors


    * Made of durable high quality material---Stainless Steel (body part)
    * 42002-0024S's performance is tested to meet OEM product
    * Also works with model SR200, SR333, SR400

    * 42002-0024S Stack Flue Sensor
    * Made of Stainless Steel material
    * DURABLE & RUSTPROOF


    Performances Of The 42002-0024S Cross Stack Flue Thermistor Temperature Sensors


    NOItemSignTest ConditionsMin.Normal valueMax.Unit
    4-1.Resistance at 200℃R200

    Ta=200±0.05℃

    PT≦0.1mw

    7.688.4
    Resistance at 150℃R150

    Ta=150±0.05℃

    PT≦0.1mw

    /29.65/
    Resistance at 250℃R250

    Ta=250±0.05℃

    PT≦0.1mw

    /2.705/
    4-2.B ValueB150/250514153005459k
    4-3.

    Dissipation

    Coefficient

    σIn the air3/mw/℃
    4-4.Time constantτIn the air//15sec
    4-5.Insulation resistance/500VDC100//
    4-6.Withstand voltage/1500V AC5//Sec
    4-7.Operating temp.range//-30/+300

    42002-0024S Cross Stack Flue Thermistor Temperature Sensors- WHEN TO USE IT ?


    A stack flue sensor, located on the exhaust elbow of a pool heater, prevents the flue gas output from exceeding 500°F
    When the stack flue sensor fails, your system will show error codes E05 or E06 to indicate that the stack flue sensor must be replaced


    Replacing Sensor,Just follow these steps


    1. Turn off the filter pump and all electrical power to the pool heater.
    2. Allow the heater to cool for at least 30 minutes before proceeding to the next step.
    3. Unbolt and remove both the upper left and upper right jackets from the heater.
    4. Disconnect the wires from the old indoor stack flue sensor.
    5. Remove the old sensor by turning it counter-clockwise with a ½” open end wrench.
    6. Install the new sensor, sealing it with a bead of RTV sealant before threading it into the exhaust elbow.

    TIP: always order these stack flue sensors in pairs. You never know that they are bad until you go to use your pool heater, and then you get the error code E05
    Only tools needed are a screwdriver and a wrench to fix E05 error messages on Pentair Mastertemp pool heaters

    Quality 42002-0024S 8K Thermistor Temperature Sensors Mastertemp Stack Flue Sensor 300C for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Dongguan Ampfort Electronics Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)