Sign In | Join Free | My burrillandco.com
Home > Bimetal Temperature Switch >

SUS 400C Auto Reset Bimetal Temperature Switch UL TUV Bulb And Capillary Thermostat

Dongguan Ampfort Electronics Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap SUS 400C Auto Reset Bimetal Temperature Switch UL TUV Bulb And Capillary Thermostat from wholesalers
     
    Buy cheap SUS 400C Auto Reset Bimetal Temperature Switch UL TUV Bulb And Capillary Thermostat from wholesalers
    • Buy cheap SUS 400C Auto Reset Bimetal Temperature Switch UL TUV Bulb And Capillary Thermostat from wholesalers
    • Buy cheap SUS 400C Auto Reset Bimetal Temperature Switch UL TUV Bulb And Capillary Thermostat from wholesalers
    • Buy cheap SUS 400C Auto Reset Bimetal Temperature Switch UL TUV Bulb And Capillary Thermostat from wholesalers
    • Buy cheap SUS 400C Auto Reset Bimetal Temperature Switch UL TUV Bulb And Capillary Thermostat from wholesalers

    SUS 400C Auto Reset Bimetal Temperature Switch UL TUV Bulb And Capillary Thermostat

    Ask Lasest Price
    Brand Name : AMPFORT
    Model Number : WKB
    Certification : CQC,UL,TUV
    Price : To be advised
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 200,000,000pcs per month
    Delivery Time : 2 Weeks
    • Product Details
    • Company Profile

    SUS 400C Auto Reset Bimetal Temperature Switch UL TUV Bulb And Capillary Thermostat


    Temperature Limiter Regulator Auto Reset Adjustable Bulb And Capillary Thermostat


    Features Of The Adjustable Bulb And Capillary Thermostat


    * Small volume

    * Insulated shell

    * Smart action

    * Long life

    * 0°F – 700°F Temperature Range
    * 250°F Maximum Ambient Temperature
    * 2 SPDT or DPDT
    * Fixed or Adjustable
    * 15-30 Amps per Switch
    * Automatic or Manual Reset



    Application Of The Adjustable Bulb And Capillary Thermostat


    * Water heate

    * Electric water boiler

    * Electric oven

    * Electric heater

    * Washing machines

    * Fryer

    * Kitchen equipment


    Main Technical Parameters Of The Adjustable Bulb And Capillary Thermostat


    Electrical performance16(3)A-250V or 10(1.8)A-400V
    Off temperatureAs customer’s requirements, temperature design range(- 35℃~+ 350℃)
    Life≥100000 cycle
    Electrical strengthAC2000V/1min
    Normal Insulation Resistance≥100MΩ
    Contact resistance≤50mΩ
    Tidal state insulation resistance≥10MΩ
    Temperature response rate≤1.0℃/min
    Minimum current200mA

    Dimensions Of The Adjustable Bulb And Capillary Thermostat (mm)



    Principle Of The Adjustable Bulb And Capillary Thermostat


    when the temperature of the object to be controlled when the temperature changes in the temperature part of the refrigerant to produce the corresponding thermal expansion and contraction of the physical phenomena (the performance of the volume change) , And the membrane cartridge connected to the temperature sensing portion is expanded or contracted. Through the leverage principle, driving the switch off action to achieve constant temperature purposes. WK series of liquid-type temperature controller with accurate temperature control, stable and reliable, open-stop temperature is small, large temperature control range, overload current and other performance characteristics.function is temperature regulation and control.


    Function Of The Adjustable Bulb And Capillary Thermostat


    Bulb and Capillary style thermostats use expanding liquid to open or close contacts in response to temperature changes. No matter which style or model you choose, all of the capillary thermostats operate using the same physics. A fluid is encapsulated in a metal tube (bulb and capillary) and when the temperature changes the fluid either expands or contracts. This fluid change moves the head which triggers a snap action switch either opening or closing the circuit.
    The bulb is typically a larger diameter tube mounted in the material flow being sampled. The capillary is a small tube that carries the fluid away from the bulb to the head. The head can be a diaphragm or bellow, which moves with the changing temperatures.
    Our capillary thermostats also offer the option of being ambient compensated to offset the differential in temperature which keeps our thermostat controls more accurate as it’s environment changes.


    Installation and precautions Of The Adjustable Bulb And Capillary Thermostat


    1. Users must be based on the characteristics of their products, the required temperature control, order models and specifications.
    2. Thermostat installation, the temperature control as much as possible the whole close to the controlled surface temperature in order to achieve accurate temperature control purposes.
    3. Installation temperature can not be pressure deformation, so as not to affect its performance.
    4. Do not let the conductive gas or conductive material into the thermostat or pollute the surface of the thermostat so as not to affect the electrical insulation properties.
    5. Install the bracket M4 screws should not be too long, otherwise it will damage the thermostat performance.
    6. Switch box is a piece of electrical ceramic to gently take to avoid damage.
    7. Bending radius of the capillary can not be less than 5mm

    SUS 400C Auto Reset Bimetal Temperature Switch UL TUV Bulb And Capillary ThermostatSUS 400C Auto Reset Bimetal Temperature Switch UL TUV Bulb And Capillary Thermostat


    Quality SUS 400C Auto Reset Bimetal Temperature Switch UL TUV Bulb And Capillary Thermostat for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Dongguan Ampfort Electronics Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)